- ssa_ela -h 7 ; To get SRN Status for ssa (output ssa0 SRN 45002enclosure0 SRN 80221)
- lscfg -vlpdisk3 -- To get details of pdisk3
- lsdev –C –c pdisk –s ssar –H –To list all pdisks or use smit Devices->SSA Disks—>SSA Physical Disks->List All Defined SSA Physical Disks
- lsdev –C –t hdisk –c disk –s ssar –H – To list SSA Logical Disks or use smit Devices->SSA Disks—> SSA Logical Disks->List All Defined SSA Logical Disks
- smit -> SSA Dsks—>SSA Physical Disks ->Show Physical to Logical SSA Disk Relationship or--for I in $(lsdev –CS1 –c pdisk –ssar –F name); do; echo “$i: “$ssaxlate –l $i);done
- lsdev -P -H --To list all devices in the Predefined Devices object class with column headers, type--The system displays a message similar to the following:(class type subclass description--logical_volume vgtype vgsubclass Volume group )
- To Remove pdisk3 follow the steps below
pdisk3, which is hdisk5go into diagsTask Selection (Diagnostics, Advanced Diagnostics, Service Aids, etc.SSA Service AidsSet Service Mode<ServerName>:pdisk3Do Identify on pdisk3 to find out where it's located
Once you find it backout to the service mode menu again and doSet or Reset Service Mode on pdisk3
This is when the drive light should come on solid and can be replacedPull old drive out and put new drive in
Thenrmdev -l pdisk3 -drmdev -l hdisk5 -d
cfgmgr
lscfg -vl pdisk3
You should see the new pdisk3
Saturday, August 6, 2011
AiX Commads
Subscribe to:
Posts (Atom)